Products
VR
Product Introduction
Industrial Refrigeration System CW-7500 for CO2 Laser Machine

Model: CW-7500

Machine Size: 105 X 71 X 133 cm (LX W X H)

Warranty: 2 years

Standard: CE, REACH and RoHS

Product Parameters
ModelCW-7500ENTYCW-7500FNTY
VoltageAC 3P 380VAC 3P 380V
Frequency50Hz60Hz
Current2.1~18.9A2.1~16.7A
Max. power consumption8.86kW8.47kW


Compressor power

5.41kW5.12kW
7.25HP6.86HP



Nominal cooling capacity

61416Btu/h
18kW
15476Kcal/h
RefrigerantR-410a
Precision±1℃
ReducerCapillary
Pump power1.1kW1kW
Tank capacity70L
Inlet and outletRp1"
Max. pump pressure6.15bar5.9bar
Max. pump flow117L/min130L/min
N.W.160Kg
G.W.182Kg
Dimension105 X 71 X 133 cm (LX W X H)
Package dimension112 X 82 X 150 cm (LX W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Cooling Capacity: 18000W

* Active cooling

* Temperature stability: ±1°C

* Temperature control range: 5°C ~35°C

* Refrigerant: R-410a

* Intelligent temperature controller

* Multiple alarm functions

* RS-485 Modbus communication function                  

* High reliability, energy efficiency and durability                                      

* Easy maintenance and mobility

* Available in 380V, 415V or 460V 


Optional Items

              

 Heater


               

Filter


Product Details
Industrial Refrigeration System CW-7500 Intelligent temperature controller T-804A
                                       

Intelligent temperature controller


The temperature controller offers high precision temperature control of ±1°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode. 

Laser Chiller CW-7500 Water Level Indicator
                                       

Easy-to-read water level indicator


The water level indicator has 3 color areas - yellow, green and red.

Yellow area - high water level.

Green area - normal water level.

Red area - low water level.  

CO2 Laser Machine Chiller CW-7500 Junction Box

                                        Junction Box

Junction Box


Professionally designed by engineers from TEYU chiller manufacturer, easy and stable wiring.

Ventilation Distance


Industrial Process Refrigeration System CW-7500 Ventilation Distance

Certificate
CO2 Laser Chiller CW-7500 Certificate
Product Working Principle


CO2 Industrial Water Chiller CW-7500 Product Working Principle

FAQ
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English