Precise Temperature Control for Laser Systems and Industrial Applications Since 2002
Language
Home
About Us
Products
Fiber Laser Chiller
Handheld Laser Welding Chiller
CO2 Laser Chiller
Ultrafast Laser & UV Laser Chiller
Air Cooled Industrial Process Chiller
Water Cooled Chiller
Machine Tool Chiller
News
Laser News
Chiller News
Company News
Industry News
Case
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Service
Contact
Chiller Operation
Home
>
Case
>
Chiller Operation
VR
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Case
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Send your inquiry
*
Name
Format error
*
E-mail
Format error
*
Phone/WhatsApp/Skype
Format error
*
Subject
Format error
*
Message
Format error
Submit
How To Replace The Heater For Industrial Chiller CWFL-6000?
Learn how to replace the heater for industrial chiller CWFL-6000 in just a few easy steps! Our video tutorial shows you exactly what to do. Click to watch this video!First, remove the air filters on both sides. Use a hex key to unscrew the upper sheet metal and remove it. This is where the heater is. Use a wrench to unscrew its cover. Pull out the heater. Unscrew the cover of the water temp probe and remove the probe. Use a cross screwdriver to remove the screws on both sides of the top of the water tank. Remove the water tank cover. Use a wrench to unscrew the black plastic nut and remove the black plastic connector. Remove the silicone ring from the connector. Replace the old black connector with a new one. Install the silicone ring and components from the inside of the water tank to the outside. Mind the up and down directions. Install the black plastic nut and tighten it with a wrench. Install the heating rod in the lower hole and the water temp probe in the upper hole. Tighten them and install the sheet metal in order. The whole process is completed.
April 14, 2023
How to Replace the Water Level Gauge for Industrial Chiller CWFL-6000
Watch this step-by-step maintenance guide from the TEYU S&A Chiller engineer team and get the job done in no time. Follow along as we show you how to disassemble the industrial chiller parts and replace the water level gauge with ease.First, remove the air gauze from the left and right sides of the chiller, then use a hex key to remove the 4 screws to disassemble the upper sheet metal. This is where the water level gauge is. Use a cross screwdriver to remove the top size screws of the water tank. Open the tank cover. Use a wrench to unscrew the nut on the outside of the water level gauge. Unscrew the fixing nut before replacing the new gauge. Install the water level gauge outward from the tank. Please note that the water level gauge must be installed perpendicular to the horizontal plane. Use a wrench to tighten the gauge fixing nuts. Finally, install the water tank cover, air gauze and sheet metal in sequence.
April 10, 2023
How To Replace The DC Pump For Chiller CWUP-20?
Firstly, use a cross screwdriver to remove the sheet metal screws. Remove the water supply inlet cap, remove the upper sheet metal, remove the black sealed cushion, identify the position of the water pump, and cut off the zip ties on the inlet and outlet of the water pump. Remove the insulation cotton on the inlet and outlet of the water pump. Use a screwdriver to remove the silicone hose on its inlet and outlet. Disconnect the power supply connection of the water pump. Use a cross screwdriver and a 7mm wrench to remove the 4 fixing screws at the bottom of the water pump. Then you can remove the old water pump. Apply some silicone gel to the inlet of the new water pump. Fit the silicone hose onto its inlet. Then apply some silicone to the outlet of the evaporator. Connect the evaporator outlet to the inlet of the new water pump. Tighten the silicone hose with zip ties. Apply silicone gel to the water pump outlet. Fit the silicone hose onto its outlet. Secure the silicone hose with a hose clamp. Manually install the 4 screws on the water pump base. Tighten the screws. Plug in the water pump power supply. Wrap the inlet and outlet with insulation cotton. Tighten with zip ties. Finally, install the upper sheet metal. Tighten the sheet metal screws. Put the black sealed cushion on the water supply inlet. Cover the water inlet with the cap and you're done.
April 05, 2023
Change to Constant Temp Mode for the Optics Circuit
Today, we will teach you the operation to switch to the constant temp mode for the chiller’s optics circuit, with the T-803A temperature controller. Press the “Menu” button for 3 seconds to enter the temperature setting until it displays the P11 parameter. Then press the “down” button to change 1 to 0. Lastly, save and exit.
February 23, 2023
How to measure industrial chiller voltage?
This video will teach you how to measure the industrial chiller voltage in a short time.First turn off the water chiller, then unplug its power cord, open the electrical connecting box, and plug the chiller back in. Turn on the chiller, when the compressor is working, measure whether the voltage of live wire and neutral wire is 220V.
February 17, 2023
Check the flow rate of the laser circuit with T-803A temperature controller
Don’t know how to check the flow rate of the laser circuit with the T-803A temperature controller? This video teaches you to get it in a short time!First, turn on the chiller, and press the pump start button, PUMP indicator on means the water pump activates. Press the button to check the operational parameter of the chiller, then press the button to find the CH3 item, the lower window displays the flow rate of 44.5L/min. It's easy to get it!
February 16, 2023
How to replace the flow switch for the industrial water chiller?
First to turn off the laser chiller, unplug the power cord, uncap the water supply inlet, remove the upper sheet metal housing, find and disconnect the flow switch terminal, use a cross screwdriver to remove the 4 screws on the flow switch, take out the flow switch top cap and the internal impeller. For the new flow switch, use the same method to remove its top cap and impeller. then install the new impeller into the original flow switch. Use the cross screwdriver to tighten the 4 fixing screws, reconnect the wire terminal and you’re done~Follow me for more tips on chiller maintenance.
December 19, 2022
How to check the room temperature and flow of industrial water chiller?
Room temperature and flow are two factors that greatly affect the industrial chiller cooling capacity. Ultrahigh room temperature and ultralow flow will affect the chiller cooling capacity. The chiller works at room temperature above 40 ℃ for a long time will cause damage to the parts. So we need to observe these two parameters in real time.First, when the chiller is turned on, take the T-607 temperature controller as an example, press the right arrow button on the controller, and enter the status display menu. "T1" represents the temperature of the room temperature probe, when the room temperature is too high, the room temperature alarm will set off. Remember to clean up the dust to improve ambient ventilation. Continue to press the "►" button, "T2" represents the flow of the laser circuit. Press the button again, "T3" represents the flow of the optics circuit. When detected a traffic drop, the flow alarm will set off. It is time to replace the circulating water, and clean the filter screen.
December 14, 2022
How to replace the heater of the industrial chiller CW-5200?
The main function of the industrial chiller heater is to keep the water temperature constant and prevent cooling water from freezing. When the cooling water temperature is lower than the set one by 0.1℃, the heater starts to work. But when the heater of the laser chiller fails, do you know how to replace it?First, turn off the chiller, unplug its power cord, uncap the water supply inlet, remove the sheet metal casing, and find and unplug the heater terminal. Loosen the nut with a wrench and take out the heater. Take down its nut and rubber plug, and reinstall them on the new heater. Lastly, insert the heater back into the original place, tighten the nut and connect the heater wire to finish.
December 12, 2022
How to replace the cooling fan of the industrial chiller CW 3000?
How to replace the cooling fan for CW-3000 chiller?First, turn off the chiller and unplug its power cord, uncap the water supply inlet, unscrew the fixing screws and remove the sheet metal, cut off the cable tie, distinguish the cooling fan’s wire and unplug it. Take away fixing clips on both sides of the fan, disconnect the fan’s ground wire, untighten the fixing screws to take out the fan from the side. Watch carefully the airfow direction when installing a new fan, don't install it backwards because the wind is blowing out of the chiller. Assemble the parts back the way you disassemble them. It is better to organize wires using a zip cable tie. Lastly, assemble the sheet metal back to finish.What else do you want to know about the maintenance of the chiller? Welcome to leave a message to us.
November 24, 2022
Water temperature of laser remains high?
Try replacing the cooling fan capacitor of the industrial water chiller!First, remove the filter screen on both sides and the power box panel. Don't get it wrong, this is the compressor starting capacitance, which needs to be removed, and the hidden one inside is the starting capacitance of cooling fan. Open the trunking cover, follow capacitance wires then you can find the wiring part, use a screwdriver to unscrew the wiring terminal, the capacitance wire can be easily taken out. Then use a wrench to unscrew the fixing nut on the back of power box, after which you can take off the starting capacitance of the fan. Install the new one on the same position, and connect wire at the corresponding position in the junction box, tighten the screw and the installation is completed.Follow me for more tips on the chiller maintenance.
November 22, 2022
Industrial Chiller CW 3000 Dust Removal
What to do if there is dust accumulation in the industrial chiller CW3000?10 seconds to help you solve this problem. First, remove the sheet metal, then use an air gun to clean the dust on the condenser. The condenser is an important cooling part of the chiller, and periodic dust cleaning is conducive to stable cooling. Follow me for more tips on chiller maintenance.
October 27, 2022
No more~~
1
2
3
Copyright © 2021 TEYU S&A Chiller - All Rights Reserved.
linkedin
whatsapp
whatsapp
facebook
twitter
share
Share
Send Inquiry
Chat Now
Send your inquiry
Name
E-mail
Format error
Phone/WhatsApp/Skype
Subject
Message
SEND INQUIRY NOW
Choose a different language
╳
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English
SEARCH
Send Your Inquiry
*
Name
*
Phone
*
E-mail
*
Message
Please enter the calculation result.
Please enter the calculation result.
Verification failed. Please re-enter.