Air Cooled Industrial Process Chiller
VR
Product Introduction
UL Certified Industrial Chiller CW-6200BN, Preferred Safety Choice in the North American Market

Model: CW-6200BN (UL)

Machine Size: 67X47X89cm (L X W X H)

Warranty: 2 years

Standard: UL, CE, REACH and RoHS

Product Parameters
ModelCW-6200BN (UL)
VoltageAC 1P 220-240V
Frequency60Hz
Current2.6~14A

Max. power consumption

2.31kW
Compressor power1.7kW
2.31HP
Nominal cooling capacity16377Btu/h
4.8kW
4127Kcal/h
Pump power0.37kW

Max. pump pressure

2.8bar

Max. pump flow

70L/min
RefrigerantR-410a
Precision±0.5℃
ReducerCapillary
Tank capacity14L
Inlet and outletOD 20mm Barbed connector
N.W.82Kg
G.W.92Kg
Dimension67X47X89cm (L X W X H)
Package dimension85X62X104cm (L X W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Cooling Capacity: 4800W

* Active cooling

* Temperature stability: ±0.5°C

* Temperature control range: 5°C ~35°C

* Refrigerant: R-410a

* User-friendly temperature controller

* Integrated alarm functions

* Back mounted water fill port and easy-to-read water level check

* High reliability, energy efficiency and durability                                             

* Simple setup and operation


Application

* Laboratory equipment (rotary evaporator, vacuum system)

* Analytical equipment (spectrometer, bio analyzes, water sampler)

* Medical diagnostic equipment(MRI, X-ray)

* Plastic molding machines

* Printing machine

* Furnace

* Welding machine

* Packaging machinery

* Plasma etching machine

* UV curing machine

* Gas generators

* Helium compressor (cryo compressors)

Product Details
Smart Thermostat of UL Certified Industrial Chiller CW-6200BN
                                     






Smart thermostat combined with RS-485 communication


The smart thermostat with RS-485 communication enables remote monitoring and control of chiller startup and shutdown, enhancing operational convenience.







Easy-to-read water level indicator of UL Certified Industrial Chiller CW-6200BN
                                       

Easy-to-read water level indicator


The water level indicator has 3 color areas - yellow, green and red.

Yellow area - high water level.

Green area - normal water level.

Red area - low water level.  

5μm sediment filter of UL Certified Industrial Chiller CW-6200BN
                                       

5μm sediment filter


The 5μm sediment filter in the chiller’s external filtration system removes fine particles from the circulating water, protecting the system, improving cooling efficiency, and reducing maintenance complexity.

Premium axial fan of UL industrial chiller CW-6200BN
                                       

Premium axial fan


The Premium axial fan in the chiller enhances airflow, improving cooling efficiency, reducing energy consumption, and ensuring quiet operation.

Ventilation Distance

UL Industrial Chiller CW-6200BN Ventilation Distance

Certificate
UL Industrial Chiller CW-6200BN Certificate
Product Working Principle

UL Industrial Chiller CW-6200BN Product Working Principle

FAQ
Is S&A Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English