industrial chiller fault

You’re in the right place for industrial chiller fault.By now you already know that, whatever you are looking for, you’re sure to find it on TEYU S&A Chiller.we guarantee that it’s here on TEYU S&A Chiller.
This product makes an impression in terms of decoration. Conveying its high quality in its appearance, it is impressive and makes a statement. .
We aim to provide the highest quality industrial chiller fault.for our long-term customers and we will actively cooperate with our customers to offer effective solutions and cost benefits.
  • Causes and Solutions for E9 Liquid Level Alarm on Industrial Chiller Systems
    Causes and Solutions for E9 Liquid Level Alarm on Industrial Chiller Systems
    Industrial chillers are equipped with multiple automatic alarm functions to ensure production safety. When an E9 liquid level alarm occurs on your industrial chiller, follow the following steps to troubleshoot and resolve the issue. If the problem is still difficult, you can try to contact the chiller manufacturer’s technical team or return the industrial chiller for repairs.
  • How To Replace The DC Pump For Chiller CWUP-20?
    How To Replace The DC Pump For Chiller CWUP-20?
    Firstly, use a cross screwdriver to remove the sheet metal screws. Remove the water supply inlet cap, remove the upper sheet metal, remove the black sealed cushion, identify the position of the water pump, and cut off the zip ties on the inlet and outlet of the water pump. Remove the insulation cotton on the inlet and outlet of the water pump. Use a screwdriver to remove the silicone hose on its inlet and outlet. Disconnect the power supply connection of the water pump. Use a cross screwdriver and a 7mm wrench to remove the 4 fixing screws at the bottom of the water pump. Then you can remove the old water pump. Apply some silicone gel to the inlet of the new water pump. Fit the silicone hose onto its inlet. Then apply some silicone to the outlet of the evaporator. Connect the evaporator outlet to the inlet of the new water pump. Tighten the silicone hose with zip ties. Apply silicone gel to the water pump outlet. Fit the silicone hose onto its outlet. Secure the silicone hose with a hose clamp. Manually install the 4 screws on the water pump base. Tighten the screws. Plug in the water pump power supply. Wrap the inlet and outlet with insulation cotton. Tighten with zip ties. Finally, install the upper sheet metal. Tighten the sheet metal screws. Put the black sealed cushion on the water supply inlet. Cover the water inlet with the cap and you're done. 
  • How to solve the laser circuit flow alarm of the industrial water chiller?
    How to solve the laser circuit flow alarm of the industrial water chiller?
    What to do if the laser circuit’s flow alarm rings? First, you can press the up or down key to check the flow rate of the laser circuit. Alarm will be triggered when the value falls below 8, it may be caused by the Y-type filter clogging of the laser circuit water outlet.Turn off the chiller, find the Y-type filter of the laser circuit water outlet, use an adjustable wrench to remove the plug anticlockwise, take out the filter screen, clean and install it back, remember not to lose the white sealing ring on the plug. Tighten the plug with wrench, if the flow rate of laser circuit is 0, it is possible that the pump is not working or the flow sensor fails. Open the left-side filter gauze, use a tissue to check whether the back of the pump will aspirate, if the tissue is sucked in, it means the pump is working normally, and there may be something wrong with the flow sensor, feel free to contact our after-sales team to solve it. If pump is not working properly, open the electric box, measure the voltage at the lower end of the leftmost alternating current contactor. See if three phases are all stable at 380V, if not, it means there is a problem with the voltage. But if the voltage is normal and stable, the flow alarm still can’t be troubleshot, please contact our after-sales team immediately.
  • What to do if the flow alarm rings in the industrial chiller CW 3000?
    What to do if the flow alarm rings in the industrial chiller CW 3000?
    What to do if the flow alarm rings in the industrial chiller CW 3000? 10 seconds to teach you to find the causes.Firstly, turn off the chiller, remove the sheet metal, unplug the water inlet pipe, and connect it to the water supply inlet. Turn on the chiller and touch the water pump, its vibration indicates the chiller works normally. Meanwhile, observe the water flow, if the water flow decreases, please immediately contact our after-sales staff.Follow me for more tips on the maintenance of chillers.
  • Industrial chiller cw 3000 fan stops rotating
    Industrial chiller cw 3000 fan stops rotating
    What to do if the cooling fan of the chiller CW-3000 does not work?This may be caused by the low ambient temperature. The low ambient temperature keeps the water temperature below 20 ℃, thus leading to its malfunction. You can add some warm water through the water supply inlet, then remove the sheet metal, find the wiring terminal beside the fan, then re-plug the terminal and check the operation of the cooling fan. If the fan is rotating normally, the fault is solved. If it still does not rotate, please immediately contact our after-sales staff.
  • How to deal with the flow alarm of the laser chiller?
    How to deal with the flow alarm of the laser chiller?
    When a laser chiller flow alarm occurs, you can press any key to stop the alarm first, then detect the relevant cause and solve it. 
  • Industrial Chiller CW-5200 Flow Alarm
    Industrial Chiller CW-5200 Flow Alarm
    What should we do if CW-5200 chiller has a flow alarm? 10 seconds to teach you to solve this chiller fault. First, turn off the chiller, short-circuit the water inlet and outlet. Then turn the power switch back on. Pinch the hose to feel the water pressure to check if the water flow is normal. Open the right side dust filter at the same time, If the pump is vibrating, it means it's working normally. Otherwise, please contact the after-sales staff as soon as possible.
CONTACT US
Just tell us your requirements, we can do more than you can imagine.

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English