3D Printer Chiller
VR
Product Introduction
High Power Closed Loop Refrigeration Chiller for 3D Printer

Model: CWFL-4000

Machine Size: 87X65X117cm (LX W XH)

Warranty: 2 years

Standard: CE, REACH and RoHS

 

Product Parameters
ModelCWFL-4000BNPTYCWFL-4000ENPTY
VoltageAC 1P 220-240VAC 3P 380V
Frequency60Hz50Hz
Current3.6~31.9A1.7~18.8A

Max. power consumption

7.3kW8.16kW

Heater power

600W+ 1800W
Precision±1℃
ReducerCapillary
Pump power1kW0.75kW
Tank capacity40L
Inlet and outletRp1/2"+Rp1"

Max. pump pressure

5.9bar
5bar
Rated flow2L/min +>40L/min
N.W.123Kg135Kg
G.W.150Kg154Kg
Dimension87X65X117cm (LX W XH)
Package dimension95X77X135cm (L X W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Precise Temperature Control: Maintains stable and accurate cooling to prevent overheating, ensuring consistent print quality and equipment stability.

* Efficient Cooling System: High-performance compressors and heat exchangers effectively dissipate heat, even during long print jobs or high-temperature applications.

* Real-Time Monitoring & Alarms: Equipped with an intuitive display for real-time monitoring and system fault alarms, ensuring smooth operation.

* RS485 Remote Control: Optional remote monitoring and control via RS485 interface, ideal for industrial environments.

* Energy-Efficient: Designed with energy-saving components to reduce power consumption without sacrificing cooling efficiency.

* Compact & Easy to Operate: Space-saving design allows for easy installation, and user-friendly controls ensure simple operation.

* International Certifications: Certified to meet multiple international standards, ensuring quality and safety in diverse markets.

* Durable & Reliable: Built for continuous use, with robust materials and safety protections, including overcurrent and over-temperature alarms.

* 2-Year Warranty: Backed by a comprehensive 2-year warranty, ensuring peace of mind and long-term reliability.

* Wide Compatibility: Suitable for various 3D printers, including SLS, SLM, and DMLS machines.



Optional Items


Heater


Water filter


US standard plug / EN standard plug

                                                                                            

Product Details
Temperature Controller T-803A of 3D Printer Chiller CWFL-4000
                                       

Dual temperature control


The intelligent control panel offers two independent temperature control systems. One is for controlling the temperature of the fiber laser and the other is for controlling the temperature of the optics.   


Water Inlet and Water Outlet of 3D Printer Chiller CWFL-4000
                                       

Dual water inlet and water outlet


Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage.

Caster wheels of 3D Printer Chiller CWFL-4000
                                       

Caster wheels for easy mobility


Four caster wheels offer easy mobility and unmatched flexibility.

Ventilation Distance

Ventilation Distance of 3D Printer Chiller CWFL-4000

Certificate
Certificate of 3D Printer Chiller CWFL-4000
Product Working Principle

Working Principle of 3D Printer Chiller CWFL-4000

FAQ
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.



Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English