fiber laser chiller

Rack mount recirculating laser chiller RMFL-2000 is developed by S&A Teyu based on the laser welding market demand and is applicable to cool 2KW handheld fiber laser welding machine. Rack mount fiber laser chiller RMFL-2000 features ±0.5℃ temperature stability with dual temperature control system which is capable of cooling the fiber laser and the laser head at the same time. In addition, it is designed with intelligent & constant temperature modes which can meet different demands in different situations. 



  Features  
1. With environmental refrigerant;
2. ±0.5℃ precise temperature control;
3. The intelligent temperature controller has 2 control modes applicable in different occasions; with various setting and display functions;
4. Dual temperature control system to satisfy different needs of fiber laser device and laser head;
5. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
6. CE approval; RoHS approval; REACH approval;
7. Optional heater and water filter.

THE WARRANTY IS 2 YEARS AND THE PRODUCT IS UNDERWRITTEN BY INSURANCE COMPANY.


  Specification  

parameter

Note: the working current can be different under different working conditions; The above information is for reference only. Please subject to the actual delivered product.


  PRODUCT INTRODUCTION  


Independent production of sheet metal, evaporator and condenser

- Adopt IPG fiber laser for welding and cutting sheet metal. 



High precision temperature control system with dual temperature control function

- Temperature control accuracy can reach ±0.5℃. High temp. for laser head and low temp. for laser device.


Multiple alarm protection

- The laser will stop working once it receives alarm signal from the water chiller for protection purpose.


temperature controller


Equipped with drain outlet.

drain outlet


Dual inlet and dual outlet connector equipped. Cooling fan of famous brand installed.

- Water Chiller inlet connects to laser outlet connector. Chiller outlet connects to laser inlet connector.

water inlet & outlet and cooling fan


Level gauge equipped

level gauge



 

  TEMPERATURE CONTROLLER PANEL DESCRIPTION  

S&A Teyu industrial water chillers are popular for its 2 temperature control modes as constant and intelligent temperature control.Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.


water chiller temp controller

Temperature controller panel description:


  Alarm function  

(1)  Alarm Display:
500W fiber laser chiller alarm display
When alarm occurs, the error code and the temperature will be alternately displayed.
(2) To suspend the alarm:
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated.



  ALARM AND OUTPUT PORTS  

In order to guarantee the equipment will not be affected while abnormal situation happens to the chiller, RMFL-1000 chiller is designed with alarm protection function.
1. Alarm output terminals and wiring diagram.
cwfl500 chillers ALARM AND OUTPUT PORTS
2. Alarm causes and working status table.
water chillers Alarm causes and working status

Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.



  CHILLER APPLICATION 

water CHILLER APPLICATION




  WAREHOUSE  
18,000 square meters brand new industrial refrigeration system research center and production base. Strictly execute ISO production management system, using mass modularized standard production. Standard parts rate up to 80%, which are the source of stable quality. 

air cooled water chillers workshop



  TEST SYSTEM  

With excellent laboratory testing system which simulates actual working environment of the chiller. Overall performance testing before delivery: aging test and complete performance test must be performed on each finished chiller.

WATER CHILLER TEST SYSTEM



Video

Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English