A Bulgarian handheld laser welding machine user had a rack mount water chiller and recently his chiller triggered E2 alarm. So what does E2 alarm suggest? Well, E2 alarm suggests the water temperature of the laser process chiller is too high. There are a few reasons and solutions for this kind of alarm.
1.If the alarm occurs to the newly bought rack mount water chiller, that could be because the chiller doesn’t have sufficient cooling capacity. In this case, change for a bigger one;After 19-year development, we establish rigorous product quality system and provide well-established after-sales service. We offer more than 90 standard water chiller models and 120 water chiller models for customization. With cooling capacity ranging from 0.6KW to 30KW, our water chillers are applicable to cool different laser sources,laser processing machines, CNC machines, medical instruments, laboratory equipment and so on.
We're here for you when you need us.
Please complete the form to contact us, and we'll be happy to help you.
Copyright © 2021 TEYU S&A Chiller - All Rights Reserved.