In some circumstances, the air cooled water chiller which cools laser metal cutting machine may trigger the alarm. There will be beeping and the error code and the water temperature alternating on the control panel of the temperature controller. In this case, users can stop the beeping by pressing any button, but the error code can’t be removed until the alarm condition is eliminated. For example, for S&A Teyu air cooled water chiller CW-6200, the error code illustrations are as follows. E1 stands for ultra-high room temperature; E2 stands for ultra-high water temperature; E3 stands for ultra-low water temperature; E4 means faulty room temperature sensor; E5 means the faulty water temperature sensor. Users need to identify the real cause first and then solve the problem accordingly.
In respect of production, S&A Teyu has invested the production equipment of more than one million yuan, ensuring the quality of a series of processes from the core components (condenser) of industrial chiller to the welding of sheet metal; in respect of logistics, S&A Teyu has set up logistics warehouses in the main cities of China, having greatly reduced the damage due to the long-distance logistics of the goods, and improved transport efficiency; in respect of after-sales service, the warranty period is two years.