Precise Temperature Control for Laser Systems and Industrial Applications Since 2002
Language
Home
About Us
Products
Fiber Laser Chiller
Handheld Laser Welding Chiller
CO2 Laser Chiller
Ultrafast Laser & UV Laser Chiller
Air Cooled Industrial Process Chiller
Water Cooled Chiller
Machine Tool Chiller
News
Laser News
Chiller News
Company News
Industry News
Case
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Service
Contact
Chiller Operation
Home
>
Case
>
Chiller Operation
VR
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Case
Chiller Application
Chiller Troubleshooting
Chiller Operation
TEYU Blog
Send your inquiry
*
Name
Format error
*
E-mail
Format error
*
Phone/WhatsApp/Skype
Format error
*
Subject
Format error
*
Message
Format error
Submit
Industrial Chiller RMFL-2000 Dust Removal And Water Level Checking
What to do if there is dust accumulation in the chiller RMFL-2000? 10 seconds to help you solve the problem.First to remove the sheet metal on the machine, use the air gun to clean the dust on the condenser. The gauge indicates the water level of the chiller, and water filled to the range between the red and yellow area is recommended.Follow me for more tips on the maintenance of chillers.
October 21, 2022
Replace The Filter Screen Of The Industrial Water Chiller
During the operation of the chiller, the filter screen will accumulate a lot of impurities. When impurities accumulated too much in the filter screen, it will easily lead to a chiller flow decrease and a flow alarm. So it needs to inspect regularly and replace the filter screen of the Y-type filter of the high and low temperature water outlet.Turn off the chiller firstly when replacing the filter screen, and use an adjustable wrench to unscrew the Y-type filter of the high-temperature outlet and the low-temperature outlet respectively. Remove the filter screen from the filter, check the filter screen, and you need to replace the filter screen if there are too many impurities in it. Notes not losing the rubber pad after replacing the filter net and putting it back in the filter. Tighten with an adjustable wrench.
October 10, 2022
Industrial water chiller CW 5200 dust removal and check water level
When using industrial chiller CW 5200, users should pay attention to cleaning the dust regularly and replacing the circulating water in time. Regular cleaning of dust can improve the chiller cooling efficiency, and timely replacement of the circulating water and keeping it at a suitable water level (within the green range) can prolong the chiller service life.First, press the button, open the dustproof plates on the left and right sides of the chiller, use an air gun to clean the dust accumulation area. The back of the chiller can check the water level, The circulating water should be controlled between red and yellow areas(within the green range).
September 21, 2022
Industrial chiller voltage measurement
During the use of an industrial water chiller, too high or too low voltage will both cause irreversible damage to the parts of the chiller, and then affect the normal operation of chiller and laser machine. It is very important to learn to detect the voltage and use the specified voltage. Let's follow S&A chiller engineer to learn how to detect the voltage, and see if the voltage you use meets the chiller instruction manual required.
August 31, 2022
Measure the starting capacitor capacity and current of laser chiller compressor
When the industrial water chiller is used for a long time, the starting capacitor capacity of the compressor will gradually decrease, which will lead to the deterioration of the cooling effect of the compressor, and even stop the compressor from working, thereby affecting the cooling effect of the laser chiller and the normal operation of the industrial processing equipment.By measuring the laser chiller compressor startup capacitor capacity and the power supply current, it can be judged whether the laser chiller compressor is working normally, and the fault can be eliminated if there is a fault; if there is no fault, it can be checked regularly to protect the laser chiller and laser processing equipment in advance.S&A chiller manufacturer specially recorded the operation demonstration video of measuring the starting capacitor capacity and current of the laser chiller compressor to help users understand and learn to solve the problem of compressor failure, better protect the laser chiller and laser equipment, and ensure that the laser equipment and its refrigeration system continues to work efficiently.
August 15, 2022
S&A laser chiller air removal process
The first time inject chiller cycling water, or after replacing the water, if a flow alarm occurs, it may be some air in the chiller pipeline that needs to be emptied. In the video is the chiller emptying operation demonstrated by the engineer of S&A laser chiller manufacturer. Hope to help you to deal with the water injection alarm problem.
July 26, 2022
Circulating water replacement process of industrial chiller
The circulating water of industrial chillers is generally distilled water or pure water (Don't use tap water because there are too many impurities in it), and it should be replaced regularly. The frequency of circulating water replacement is determined according to the operating frequency and use environment, the low-quality environment is changed once per half a month to a month. the ordinary environment is changed once per three months, and the high-quality environment can change once per year. In the process of replacing the chiller circulating water, the correctness of the operation process is very important. The video is the operation process of replacing the chiller circulating water demonstrated by the S&A chiller engineer. Come and see whether your replacement operation is correct!
July 23, 2022
The correct chiller dust removal methods
After the chiller runs for some time, a lot of dust will accumulate on the condenser and dust net. If the accumulated dust is not handled in time or improperly handled, it will cause the internal temperature of the machine to rise and the cooling capacity to drop, which will seriously lead to machine failure and shortened service life. So, how can we effectively dedust the chiller? Let's follow the S&A engineers to learn the correct chiller dust removal method in the video.
July 18, 2022
Precautions for first-time installation of industrial chillers
The matters that need attention during the initial installation of the chiller have five points: making sure the accessories are complete, ensuring the working voltage of the chiller is stable and normal, matching the power frequency, forbidden to run without water, and making sure that the air inlet and outlet channels of the chiller are smooth!
May 24, 2022
No more~~
1
2
3
Copyright © 2021 TEYU S&A Chiller - All Rights Reserved.
linkedin
whatsapp
whatsapp
facebook
twitter
share
Share
Send Inquiry
Chat Now
Send your inquiry
Name
E-mail
Format error
Phone/WhatsApp/Skype
Subject
Message
SEND INQUIRY NOW
Choose a different language
╳
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English
SEARCH
Send Your Inquiry
*
Name
*
Phone
*
E-mail
*
Message
Please enter the calculation result.
Please enter the calculation result.
Verification failed. Please re-enter.