S&A Industrial chiller expert16 years experience in chiller research, development, manufacture and sale
ROHSCEISOREACH
Email:marketing@teyu.com.cnTel:+86-20-89301885
laser marking machine water chiller
Current location: HomeNews Center » News Center » Hot News » how to set for example min 17 degrees C and max. 18 degrees for S&A chiller CW-6000?

Recommended Products

Chiller CW-5300 1800W cooling capacity
Chiller CW-5300 1800W cooling capacity
1. 1800W cooling capacity; optional environmental refrigerant; 2. ±0.3? precisely temperature control; 3. The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;
Water chiller CWFL-1500 for 1500W fiber laser
Water chiller CWFL-1500 for 1500W fiber laser
S&A refrigeration industrial water chiller CWFL-1500 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. CWFL-1500 chiller is special applied for cooling 1500W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
water chiller CWFL-500 for 500W fiber laser
water chiller CWFL-500 for 500W fiber laser
S&A compressor refrigeration water chiller CWFL-500 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. CWFL-500 chiller is special applied for cooling 500W fiber lase
Chiller CW-7900 30KW refrigeration capacity
Chiller CW-7900 30KW refrigeration capacity
S&A CW-7900 remote control series is high-precision compression refrigeration small water chiller,available for remote control,with intelligent temperature control,completed configuration,perfect protection and alarm system. Features 1. 30KW cooling capacity; optional environmental refrigerant; 2. ±1? precisely temperature control;
Water chiller CWFL-6000 for 6000W fiber laser
Water chiller CWFL-6000 for 6000W fiber laser
S&A high power refrigeration industrial water chiller CWFL-6000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd.CWFL-6000 chiller is special applied for cooling 6000W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Chiller CW-3000 50W/? radiating capacity
Chiller CW-3000 50W/? radiating capacity
S&A cw-3000 is thermolysis type industrial water cooler. It’s mainly used on the equipment for heat exchange between the heat and the air environment. The water temperature of cw-3000 cooler is related to ambient temperature, so it's thermostat is not manually adjusted.
Water chiller CWFL-800 for 800W fiber laser
Water chiller CWFL-800 for 800W fiber laser
S&A industrial water chiller CWFL-800 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. CWFL-800 chiller is special applied for cooling 800W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Chiller CW-5000 800W cooling capacity
Chiller CW-5000 800W cooling capacity
S&A CW-5000 is refrigeration type industrial water chiller of 800W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There is 1 water outlet and an inlet, applicable to cool single laser glass tube.

Top articles

Latest articles

Your browsing history

    Loading...

how to set for example min 17 degrees C and max. 18 degrees for S&A chiller CW-6000?

Categories: Hot NewsStars: 3Stars Visit: - Release time: 2016-04-20 04:52:00
RSS subscription Font size:【 Large Middle Small Source: www.teyuchiller.com Editor: chiller Author: S&A
1. Restore to factory setting.
    Turn off the chiller first. Press and keep holding ▲and▼buttons then turn on the chiller. Do not release the buttons until the controller
    display rE.
how to set for example min 17 degrees C and max. 18 degrees for S&A chiller CW-6000?

2. To set the temperature: 
     "SET" : enter    
    "RST": save and exit (save the modification and exit when you have finished your modification)
    ▲or▼: to switch item / digit
 
(1) Press ▲ key and hold it, then press "SET" button for 5 seconds until "00" displayed in upper window and "PAS" in lower window.
     Meanwhile, press▲button to switch to "8", then press "SET" button and it displays "F0".
 
(2) Press ? to turn to "F3" and press ▼ to adjust "1" to "0".
 
(3) Press ? to turn to "F0" and press ▲or ▼ to adjust "25" (supposing this is the target water temp.) .

(4) Press ? to turn to "F9" and press ▲or ▼ to adjust "20"  or other you need (F9 value must be lower than F0, if not the chiller will stop
    refrigerating when the temp reached F9 value). At last,  press "RST" button to save all the modification and exit menu.

The controller of your chiller is T-506/T-506H. Below is the default settings.