S&A Industrial chiller expert16 years experience in chiller research, development, manufacture and sale
ROHSCEISOREACH
Email:marketing@teyu.com.cnTel:+86-20-89301885
laser marking machine water chiller
Current location: HomeNews Center » News Center » Hot News » Customer reflect the water temperature fails to drop when both laser machine and chiller are working well

Recommended Products

Water chiller CWFL-2000 for 2000W fiber laser
Water chiller CWFL-2000 for 2000W fiber laser
S&A compressor refrigeration industrial water chiller CWFL-2000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd.CWFL-2000 chiller is special applied for cooling 2000W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Chiller CW-6200 5100W cooling capacity
Chiller CW-6200 5100W cooling capacity
S&A CW-6200 series is high-precision compression refrigeration small water chiller,with intelligent temperature control,completed configuration,perfect protection and alarm system. Features 1. 5100W cooling capacity; optional environmental refrigerant; 2. ±0.5? precisely temperature control;
Chiller CW-6000 3000W cooling capacity
Chiller CW-6000 3000W cooling capacity
CW-6000 series industrial water chiller of 3000W cooling capacity is produced by Guangzhou Teyu Electromechanical Co., Ltd. It can be used to cool high-power lasers and high-speed spindles, etc. S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control
Chiller CW-7900 30KW refrigeration capacity
Chiller CW-7900 30KW refrigeration capacity
S&A CW-7900 remote control series is high-precision compression refrigeration small water chiller,available for remote control,with intelligent temperature control,completed configuration,perfect protection and alarm system. Features 1. 30KW cooling capacity; optional environmental refrigerant; 2. ±1? precisely temperature control;
Chiller CW-6100 4200W cooling capacity
Chiller CW-6100 4200W cooling capacity
S&A CW-6100 series is high-precision compression refrigeration small water chiller,with intelligent temperature control,completed configuration,perfect protection and alarm system. S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control.
Water chiller CWFL-12000 for 12000W fiber laser
Water chiller CWFL-12000 for 12000W fiber laser
S&A high power refrigeration industrial water chiller CWFL-12000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Water chiller CWFL-6000 for 6000W fiber laser
Water chiller CWFL-6000 for 6000W fiber laser
S&A high power refrigeration industrial water chiller CWFL-6000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd.CWFL-6000 chiller is special applied for cooling 6000W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Chiller CW-6300 8500W cooling capacity
Chiller CW-6300 8500W cooling capacity
S&A CW-6300 series is high-precision compression refrigeration water chiller,with intelligent temperature control,completed configuration,perfect protection and alarm system. Features 1. 8500W cooling capacity; optional environmental refrigerant; 2.±1? precisely temperature control;

Top articles

Latest articles

Your browsing history

    Loading...

Customer reflect the water temperature fails to drop when both laser machine and chiller are working well

Categories: Hot NewsStars: 3Stars Visit: - Release time: 2014-06-19 03:09:00
RSS subscription Font size:【 Large Middle Small Source: www.teyuchiller.com Editor: Chiller Author: S&A

S&A after-sales department often receive the problems from customer that why the laser chiller displays over high water temperature,but the refrigeration system is running normally.

Now,I show you some simple judgement method and troubleshooting.
1. Please make sure the cooling capacity of the laser chiller is enogh and match with laser machine. For example, because the customer choose wrong chiller model (not enought cooling capacity), it's not able to cool down the water for laser machine. In this situation, it should be another chiller model with larger cooling capacity.
2. After long term running without cleaning and too must dust accumulating, the filter gauze needs to be uninstalled and washed. Besides, clean the interior dust of the chiller and wash the water route.
3. If the water still can not be cooled down after above mentioned 2 solutions, it could be judged as temperature controller of malfunction. User can contact S&A after-sales department for support: 4006002093 ext.2
water chiller
More S&A chiller lastest information: http://www.teyuchiller.com/HotNews.shtml

Keywords in the article: water temperature aser machine chiller